1.
Sci Rep ; 14(1): 629, 2024 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-38182740

RESUMO

A growing literature suggests that plasma levels of tau phosphorylated at amino acid 217 (pTau217) performs similarly to cerebrospinal fluid (CSF) biomarkers and PET imaging to detect amyloid pathology and to provide diagnostic and prognostic information in Alzheimer's disease (AD), but a significant limiting factor thus far has been a lack of widely available immunoassays. We evaluated a novel pTau217 S-PLEX® assay developed by Meso Scale Discovery (MSD; Rockville, MD) in plasma from 131 individuals with AD confirmed by CSF biomarkers and controls. Technical performance of the assay was excellent with an LLOQ of 1.84 pg/mL and intra/interplate CVs of 5.5% (0.3-15.0%) and 5.7% (range 0.3-13.4%), respectively. The pTau217 plasma assay differentiated AD and controls with an AUC of 0.98 (95% CI 0.96-1.0) and pTau217 levels were 3.9-fold higher in individuals with AD. This performance was significantly better than what was observed for plasma pTau181, performed in parallel, and comparable to published data on existing pTau217 assays. While further clinical validation and head-to-head comparisons are needed to fully establish the role for the novel pTau217 S-PLEX assay, these data demonstrate the utility of the assay to detect AD pathology.


Assuntos
Doença de Alzheimer , Humanos , Doença de Alzheimer/diagnóstico por imagem , Testes Imunológicos , Aminoácidos , Proteínas Amiloidogênicas , Biomarcadores
2.
Anal Chem ; 88(18): 9269-75, 2016 09 20.
Artigo em Inglês | MEDLINE | ID: mdl-27558535

RESUMO

Parathyroid hormone-related peptide (PTHrP) is recognized as the major causative agent of humoral hypercalcemia of malignancy (HHM). The paraneoplastic PTHrP has also been implicated in tumor progression and metastasis of many human cancers. Conventional PTHrP detection methods like immunoradiometric assay (IRMA) lack the sensitivity required to measure target peptide levels prior to the development of hypercalcemia. In general, sensitive, multiplexed peptide measurement by immunoassay represents challenges that we address in this paper. We describe here the first ultrasensitive multiplexed peptide assay to measure intact PTHrP 1-173 as well as circulating N-terminal and C-terminal peptide fragments. This versatile approach should apply to almost any collection of peptides that are long enough to present binding sites for two antibodies. To target PTHrP, we employed a microfluidic immunoarray featuring a chamber for online capture of the peptides from serum onto magnetic beads decorated with massive numbers of peptide-specific antibodies and enzyme labels. Magnetic bead-peptide conjugates were then washed and sent to a detection chamber housing an antibody-modified 8-electrode array fabricated by inkjet printing of gold nanoparticles. Limits of detection (LODs) of 150 aM (∼1000-fold lower than IRMA) in 5 µL of serum were achieved for simultaneous detection of PTHrP isoforms and peptide fragments in 30 min. Good correlation for patient samples was found with IRMA (n = 57); r(2) = 0.99 assaying PTHrP 1-86 equiv fragments. Analysis by a receiver operating characteristic (ROC) plot gave an area under the curve of 0.96, 80-83% clinical sensitivity, and 96-100% clinical specificity. Results suggest that PTHrP1-173 isoform and its short C-terminal fragments are the predominant circulating forms of PTHrP. This new ultrasensitive, multiplexed assay for PTHrP and fragments is promising for clinical diagnosis, prognosis, and therapeutic monitoring from early to advanced stage cancer patients and to examine underlying mechanisms of PTHrP overproduction.


Assuntos
Imunoensaio/instrumentação , Neoplasias/sangue , Proteína Relacionada ao Hormônio Paratireóideo/sangue , Análise Serial de Proteínas/instrumentação , Anticorpos Imobilizados/química , Desenho de Equipamento , Humanos , Limite de Detecção , Neoplasias/diagnóstico , Proteína Relacionada ao Hormônio Paratireóideo/análise , Isoformas de Proteínas/análise , Isoformas de Proteínas/sangue
3.
Analyst ; 141(2): 536-47, 2016 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-26525998

RESUMO

Early detection and reliable diagnostics are keys to effectively design cancer therapies with better prognoses. The simultaneous detection of panels of biomarker proteins holds great promise as a general tool for reliable cancer diagnostics. A major challenge in designing such a panel is to decide upon a coherent group of biomarkers which have higher specificity for a given type of cancer. The second big challenge is to develop test devices to measure these biomarkers quantitatively with high sensitivity and specificity, such that there are no interferences from the complex serum or tissue matrices. Lastly, integrating all these tests into a technology that does not require exclusive training to operate, and can be used at point-of-care (POC) is another potential bottleneck in futuristic cancer diagnostics. In this article, we review electrochemistry-based tools and technologies developed and/or used in our laboratories to construct low-cost microfluidic protein arrays for the highly sensitive detection of a panel of cancer-specific biomarkers with high specificity which at the same time has the potential to be translated into POC applications.


Assuntos
Eletroquímica/economia , Eletroquímica/métodos , Imunoensaio/economia , Imunoensaio/métodos , Limite de Detecção , Neoplasias/diagnóstico , Proteínas/análise , Automação , Humanos
4.
Anal Bioanal Chem ; 407(23): 7239-43, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26143063

RESUMO

In addition to disease diagnostics, there is a need for biomarkers to predict severity of cancer therapy side effects such as oral mucositis. Oral mucositis is an inflammatory lesion of oral mucosa caused by high-dose chemotherapy and/or radiation that is especially prevalent during oral cancer treatment. We describe here a semi-automated, modular microfluidic immunoarray optimized for ultrasensitive detection of pro-inflammatory cytokines involved in pathobiology of oral mucositis. Our goal is to methodologically identify risk of mucositis early in oral cancer treatment, before the onset of lesions. Biomarkers include tumor necrosis factor alpha (TNF-α), interleukin-6 (IL-6), interleukin-1ß (IL-1ß), and C-reactive protein (CRP). Protein analytes were captured from serum in a capture chamber by 1-µm magnetic beads coated with antibodies and enzyme labels. Beads are then transported downstream to a detection chamber containing an eight-sensor array coated with glutathione-coated gold nanoparticles (GSH-AuNP) and a second set of antibodies to capture the beads with analyte proteins. In this first application of the immunoarray to four-protein multiplexed measurements, ultralow detection limits of 10-40 fg mL(-1) in 5 µL serum were achieved for simultaneous detection in 30 min. Mass detection limits were 2.5-10 zmol, as few as 1500 molecules. Accuracy and diagnostic utility of the arrays were demonstrated by correlation of levels of the four biomarker proteins in serum from head and neck cancer patients with results from standard ELISA. This approach may lead to rapid, low-cost estimates of projected risk for severity of oral mucositis in cancer patients to enable improved therapeutic management.


Assuntos
Proteína C-Reativa/análise , Citocinas/sangue , Separação Imunomagnética/instrumentação , Análise Serial de Proteínas/instrumentação , Estomatite/sangue , Estomatite/diagnóstico , Biomarcadores/sangue , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Mediadores da Inflamação/sangue , Dispositivos Lab-On-A-Chip , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Biosens Bioelectron ; 53: 268-74, 2014 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-24144557

RESUMO

Accurate, sensitive, multiplexed detection of biomarker proteins holds significant promise for personalized cancer diagnostics. Here we describe the incorporation of a novel on-line chamber to capture cancer biomarker proteins on magnetic beads derivatized with 300,000 enzyme labels and 40,000 antibodies into a modular microfluidic immunoarray. Capture and detection chambers are produced from PDMS on machined molds and do not require lithography. Protein analytes are captured from serum or other biological samples in the stirred capture chamber on the beads held in place magnetically. The beads are subsequently washed free of sample components, and wash solutions sent to waste. Removal of the magnet and valve switching sends the magnetic bead-protein bioconjugates into a detection chamber where they are captured on 8 antibody-decorated gold nanoparticle-film sensors and detected amperometrically. Most steps in the immunoassay including protein capture, washing and measurement are incorporated into the device. In simultaneous assays, the microfluidic system gave ultralow detection limits of 5 fg mL(-1) for interleukin-6 (IL-6) and 7 fg mL(-1) for IL-8 in serum. Accuracy was demonstrated by measuring IL-6 and IL-8 in conditioned media from oral cancer cell lines and showing good correlations with standard ELISAs. The on-line capture chamber facilitates rapid, sensitive, repetitive protein separation and measurement in 30 min in a semi-automated system adaptable to multiplexed protein detection.


Assuntos
Biomarcadores Tumorais/isolamento & purificação , Técnicas Biossensoriais/métodos , Técnicas Analíticas Microfluídicas , Neoplasias Bucais/diagnóstico , Anticorpos , Técnicas Biossensoriais/instrumentação , Linhagem Celular Tumoral , Ouro/química , Humanos , Imunoensaio , Magnetismo , Neoplasias Bucais/enzimologia , Neoplasias Bucais/genética , Nanopartículas/química
SELEÇÃO DE REFERÊNCIAS